Home » Product » Power Cable » Medium Voltage POWER CABLE DIN VDE 0295
Medium Voltage POWER CABLE DIN VDE 0295

Medium Voltage POWER CABLE DIN VDE 0295

Nominal voltage: 6/10KV 12/20 KV 18/30 KV 20/36KV
Maximal operating temperature: +90℃ 
At short circuit of max.5s: 250℃ 
Minimal inner bending radius: 15D single core
Single core power cable or Multi core power cable

We're here to help :easy way to get the answer you need.

SEND E-MAIL GET PRICE

PRODUCT DETAILS

Medium voltage POWER CABLE DIN VDE 0295

Product Application

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability. Used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

Product Structure

Conductor: Cu round conductor, multi wire stranded compacted (RM), class 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295

Inner screen: extruded semi-conductive skin on conductor

Insulation: XLPE (cross-linked polyethylene, recent mark: PE-X) compound DIX 8 acc. to HRN HD 620 S1

External screen: extruded semi-conductive skin on insulation, longitudinally spliced with insulation (+ tape of conductive material)

Concentric conductor: in inner layer corrugated spirally wrapped copper wires, in external layer copper tape wrapped in counter-helix

Separating: tape

Sheath: PVC compound DMV-6 acc. to HRN HD 620 S1

Related code

Type

Description

N2XSY

Medium voltage single core cable 6/10 kV,  12/20 kV, 18/30 kV, XLPE insulated, PVC sheathed, with screen of Cu  conductors


N2XS2Y

Medium voltage single core cable 6/10 kV,  12/20 kV, 18/30 kV, XLPE insulated, PE sheathed, with screen of Cu  conductors


N2XS(F)2Y

Medium voltage single core cable 6/10 kV, 12/20 kV, 18/30  kV, XLPE insulated, PE sheathed, with screen of Cu conductors, longitudinally  watertight


NA2XSY

Medium voltage single core cable 6/10 kV, 12/20 kV, 18/30  kV, XLPE insulated, PVC sheathed, with Al conductors and screen of Cu  conductors

NA2XS2Y

Medium voltage single core cable 6/10 kV, 12/20 kV, 18/30  kV, XLPE insulated, PE sheath, with Al conductors and screen of Cu conductors

NA2XS(F)2Y

Medium voltage single core cable 6/10 kV, 12/20 kV, 18/30  kV, XLPE insulated, PE sheathed, with Al conductors and screen of Cu  conductors, longitudinally watertight

N2XSEY

Medium voltage multi core cable 6/10 kV, XLPE insulated,  PVC sheathed, with screens of Cu conductors